Print this page
Document obsolescence of ualarm.

Split Close
Expand all
Collapse all
          --- old/usr/src/man/man3c/ualarm.3c
          +++ new/usr/src/man/man3c/ualarm.3c
   1      -'\" te
   2    1  .\"  Copyright (c) 1980 Regents of the University of California.  All rights reserved.  The Berkeley software License Agreement specifies the terms and conditions for redistribution.  Copyright (c) 2002, Sun Microsystems, Inc.  All Rights Reserved  Portions Copyright (c) 1992,
   3    2  .\" X/Open Company Limited  All Rights Reserved
   4    3  .\" Sun Microsystems, Inc. gratefully acknowledges The Open Group for permission to reproduce portions of its copyrighted documentation. Original documentation from The Open Group can be obtained online at
   5    4  .\" http://www.opengroup.org/bookstore/.
   6    5  .\" The Institute of Electrical and Electronics Engineers and The Open Group, have given us permission to reprint portions of their documentation. In the following statement, the phrase "this text" refers to portions of the system documentation. Portions of this text are reprinted and reproduced in electronic form in the Sun OS Reference Manual, from IEEE Std 1003.1, 2004 Edition, Standard for Information Technology -- Portable Operating System Interface (POSIX), The Open Group Base Specifications Issue 6, Copyright (C) 2001-2004 by the Institute of Electrical and Electronics Engineers, Inc and The Open Group. In the event of any discrepancy between these versions and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Standard is the referee document. The original Standard can be obtained online at http://www.opengroup.org/unix/online.html.
   7    6  .\"  This notice shall appear on any product containing this material.
   8      -.TH UALARM 3C "Aug 14, 2002"
   9      -.SH NAME
  10      -ualarm \- schedule signal after interval in microseconds
  11      -.SH SYNOPSIS
  12      -.LP
  13      -.nf
  14      -#include <unistd.h>
  15      -
  16      -\fBuseconds_t\fR \fBualarm\fR(\fBuseconds_t\fR \fIuseconds\fR, \fBuseconds_t\fR \fIinterval\fR);
  17      -.fi
  18      -
  19      -.SH DESCRIPTION
  20      -.sp
  21      -.LP
  22      -The \fBualarm()\fR function causes the \fBSIGALRM\fR signal to be generated for
        7 +.Dd "Jul 22, 2014"
        8 +.Dt UALARM 3C
        9 +.Os
       10 +.Sh NAME
       11 +.Nm ualarm
       12 +.Nd schedule signal after interval in microseconds
       13 +.Sh SYNOPSIS
       14 +.In unistd.h
       15 +.Ft useconds_t
       16 +.Fn ualarm "Buseconds_t useconds" "useconds_t interval"
       17 +.Sh DESCRIPTION
       18 +The
       19 +.Fn ualarm
       20 +function causes the
       21 +.Dv SIGALRM
       22 +signal to be generated for
  23   23  the calling process after the number of real-time microseconds specified by the
  24      -\fIuseconds\fR argument has elapsed.  When the \fIinterval\fR argument is
       24 +.Fa useconds argument has elapsed.  When the
       25 +.Fa interval
       26 +argument is
  25   27  non-zero, repeated timeout notification occurs with a period in microseconds
  26   28  specified by the \fIinterval\fR argument. If the notification signal,
  27      -\fBSIGALRM\fR, is not caught or ignored, the calling process is terminated.
  28      -.sp
  29      -.LP
       29 +.Dv SIGALRM ,
       30 +is not caught or ignored, the calling process is terminated.
       31 +.Lp
  30   32  Because of scheduling delays, resumption of execution when the signal is caught
  31   33  may be delayed an arbitrary amount of time.
  32      -.sp
  33      -.LP
  34      -Interactions between \fBualarm()\fR and either \fBalarm\fR(2) or
  35      -\fBsleep\fR(3C) are unspecified.
  36      -.SH RETURN VALUES
  37      -.sp
  38      -.LP
  39      -The \fBualarm()\fR function returns the number of microseconds remaining from
  40      -the previous \fBualarm()\fR call.  If no timeouts are pending or if
  41      -\fBualarm()\fR has not previously been called, \fBualarm()\fR returns \fB0\fR.
  42      -.SH ERRORS
  43      -.sp
  44      -.LP
       34 +.Lp
       35 +Interactions between
       36 +.Fn ualarm
       37 +and either
       38 +.Xr alarm 2
       39 +or
       40 +.Xr sleep 3C
       41 +are unspecified.
       42 +.Sh RETURN VALUES
       43 +The
       44 +.Fn ualarm
       45 +function returns the number of microseconds remaining from
       46 +the previous
       47 +.Fn ualarm
       48 +call.  If no timeouts are pending or if
       49 +.Fn ualarm
       50 +has not previously been called,
       51 +.Fn ualarm
       52 +returns 0.
       53 +.Sh ERRORS
  45   54  No errors are defined.
  46      -.SH USAGE
  47      -.sp
  48      -.LP
  49      -The \fBualarm()\fR function is a simplified interface to \fBsetitimer\fR(2),
  50      -and uses the \fBITIMER_REAL\fR interval timer.
  51      -.SH ATTRIBUTES
  52      -.sp
  53      -.LP
  54      -See \fBattributes\fR(5) for descriptions of the following attributes:
  55      -.sp
  56      -
  57      -.sp
  58      -.TS
  59      -box;
  60      -c | c
  61      -l | l .
  62      -ATTRIBUTE TYPE  ATTRIBUTE VALUE
  63      -_
  64      -Interface Stability     Standard
  65      -.TE
  66      -
  67      -.SH SEE ALSO
  68      -.sp
  69      -.LP
  70      -\fBalarm\fR(2), \fBsetitimer\fR(2), \fBsighold\fR(3C), \fBsignal\fR(3C),
  71      -\fBsleep\fR(3C), \fBusleep\fR(3C), \fBattributes\fR(5), \fBstandards\fR(5)
       55 +.Sh USAGE
       56 +The
       57 +.Fn ualarm
       58 +function is a simplified interface to
       59 +.Xr setitimer 2 ,
       60 +and uses the
       61 +.Dv ITIMER_REAL
       62 +interval timer. It's use has been deprecated in favor of the
       63 +.Xr timer_create 3C
       64 +family of functions.
       65 +.Sh INTERFACE STABILITY
       66 +.Sy Obsolete Standard .
       67 +.Sh SEE ALSO
       68 +.Xr alarm 2 ,
       69 +.Xr setitimer(2),
       70 +.Xr sighold 3C ,
       71 +.Xr signal 3C ,
       72 +.Xr sleep 3C ,
       73 +.Xr timer_create 3C ,
       74 +.Xr usleep 3C ,
       75 +.Xr standards 5
       76 +.Sh STANDARDS
       77 +The
       78 +.Fn ualarm
       79 +function was introduced in
       80 +.Bx 4.3
       81 +and standardized in
       82 +.St -xpg4.2 .
       83 +It was subsequently obsoleted in
       84 +.St -p1003.1-2001
       85 +and removed from
       86 +.St -p1003.1-2008 .
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX