1 #!/bin/ksh -p
   2 #
   3 # CDDL HEADER START
   4 #
   5 # The contents of this file are subject to the terms of the
   6 # Common Development and Distribution License (the "License").
   7 # You may not use this file except in compliance with the License.
   8 #
   9 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  10 # or http://www.opensolaris.org/os/licensing.
  11 # See the License for the specific language governing permissions
  12 # and limitations under the License.
  13 #
  14 # When distributing Covered Code, include this CDDL HEADER in each
  15 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  16 # If applicable, add the following below this CDDL HEADER, with the
  17 # fields enclosed by brackets "[]" replaced with your own identifying
  18 # information: Portions Copyright [yyyy] [name of copyright owner]
  19 #
  20 # CDDL HEADER END
  21 #
  22 
  23 #
  24 # Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
  25 # Use is subject to license terms.
  26 #
  27 
  28 #
  29 # Copyright (c) 2013 by Delphix. All rights reserved.
  30 #
  31 
  32 . $STF_SUITE/tests/functional/redundancy/redundancy.kshlib
  33 
  34 #
  35 # DESCRIPTION:
  36 #       A raidz2 pool can withstand 2 devices are failing or missing.
  37 #
  38 # STRATEGY:
  39 #       1. Create N(>3,<5) virtual disk files.
  40 #       2. Create raidz2 pool based on the virtual disk files.
  41 #       3. Fill the filesystem with directories and files.
  42 #       4. Record all the files and directories checksum information.
  43 #       5. Damaged at most two of the virtual disk files.
  44 #       6. Verify the data is correct to prove raidz2 can withstand 2 devices
  45 #          are failing.
  46 #
  47 
  48 verify_runnable "global"
  49 
  50 log_assert "Verify raidz2 pool can withstand two devices are failing."
  51 log_onexit cleanup
  52 
  53 typeset -i cnt=$(random 3 5)
  54 setup_test_env $TESTPOOL raidz2 $cnt
  55 
  56 #
  57 # Inject data corruption errors for raidz2 pool
  58 #
  59 for i in 1 2; do
  60         damage_devs $TESTPOOL $i "label"
  61         log_must is_data_valid $TESTPOOL
  62         log_must clear_errors $TESTPOOL
  63 done
  64 
  65 #
  66 # Inject bad devices errors for raidz2 pool
  67 #
  68 for i in 1 2; do
  69         damage_devs $TESTPOOL $i
  70         log_must is_data_valid $TESTPOOL
  71         log_must recover_bad_missing_devs $TESTPOOL $i
  72 done
  73 
  74 #
  75 # Inject missing device errors for raidz2 pool
  76 #
  77 for i in 1 2; do
  78         remove_devs $TESTPOOL $i
  79         log_must is_data_valid $TESTPOOL
  80         log_must recover_bad_missing_devs $TESTPOOL $i
  81 done
  82 
  83 log_pass "Raidz2 pool can withstand two devices are failing passed."